Precast Gels NuSep - NN

Original NuSep Tris-Glycine Precast Gels NN-Series.

NuSep Gele NN are suitable for Invitrogen™ Novex® XCell I und II, SureLock™ and Thermofisher XCell Mini Tank.

10 gels per box (10x10 cm).

Request a quote

Tris-Glycine Precast Gels - NN

Simply place your gel over a 250/320 nm UV transilluminator and watch high-resolution band appear in just zwei minutes. Taking you from analysis to results faster than any other gel on the market.

With nUView technology you no longer have to stain and de-stain your gels.
Increasing protein recovery and saving you significant time while receiving improved results.

NuSep high-resolution bands

Visualize Bands in 2 Minutes.
All nUView precast gels incorporate a unique formulation allowing protein bands to be visualized in only 2 minutes in the presence of ultraviolet (UV) light. Simply place your gel over a 250-320 nm UV trans-illuminator and watch high-resolution bands appear in just 2 minutes. With nUView technology you no longer have to stain and de-stain your gels – increasing protein recovery and saving you significant time while receiving improved results.

Run Times from 30 Minutes.
Reduces the time to run the gels.

Increased Resolution.
nUView Tris-Glycine gels are formulated to run at a constant 250 volts rather than 150 volts for the Laemmli gel (when using the Tris-Glycine/SDS running buffer). The higher voltage reduces the run time to 30 minutes compared to the 90 minutes with the Laemmli gel while maintaining a high resolution separation.

Longer Shelf Life.
With a 24-month shelf life (4°C) from date of manufacture or 6 months at room temperature (25°C), NuSep gels provide reproducible results time after time.

Broader Migration Range.
nUView Tris-Glycine gels offer greater resolution across a wider mass range (205 kDa to 2.5kDa). Migration patterns are available in a broad range of formulations and well configurations.

Easy to Use.
NuSep precast gels are easy to use and contain a tear open pouch and tapeless cassette for fast set up plus trouble-free cassette loading and opening (requiring no key or knife to open).
All the cassettes have large sample well capacities (up to 50 μL) with numbered lanes and solid well dividers for easy well identification – eliminating cross sample contamination and gel damage.

Running Buffers.
We will recommend to use Tris-Glycine SDS running buffer (BG-143)

Accessories.
NuSep offers a broad range of buffers, stains and drying solutions.

Satisfies Standard Protocols.
All standard western blotting protocols and all standard in-gel digestion protocols for Mass Spectrometry analysis can be used with NuSep nUView gels.

nUView - Tris-Glycine Precast Gels NN

Compatible TanksInvitrogen™ Novex® XCell I and II,
SureLock™ and Thermofisher XCell Mini Tank
Run Time50 minutes
UV Visualizationin 2 minutes
Recommended Voltage250 V
SDS in gel*No
Cassette Size (W x D x H)10 x 10 x 0.7 cm
Gel Size (W x D x H)8 x 8.8 x 0.1 cm
Available Acrylamide8%, 10%, 12%, 8-16%, 4-20%
Recommended Sample BufferTruSep Sample Buffer
Recommended Running BufferTris-glycine SDS
Storage Condition and Shelf LifeStorage at 4°C = 24 Months
Storage at RT = 6 Months
Packaging Unit10 Gels/Box

*The gels do not contain SDS (SDS is incorporated in the running buffer solution). The gels can be used for native runs.

Separation Range10 Well (50 µl)12 Well (30 µl)17 Well (20 µl) 
8% (200-45 kDa)NN10-008 / 102.0615NN12-008 / 102.0620NN17-008 / 102.0625
10% (200-10 kDa)NN10-010 / 102.0616NN12-010 / 102.0621NN17-010 / 102.0626
12% (200-21 kDa)NN10-012 / 102.0617NN12-012 / 102.0622NN17-012 / 102.0627
8 - 16% (200-10 kDa)NN10-816 / 102.0618NN12-816 / 102.0623NN17-816 / 102.0628
4 - 20% (200-6,5 kDa)NN10-420 / 102.0619NN12-420 / 102.0624NN17-420 / 102.0629

Puffer, Stains und Zubehör

NuSep Buffer zeichnen sich durch große Reinheit aus.

BezeichnungArtikelnummer    
Mini Spin Sample Prep KitDB-001
Sample ClearUp Prep KitDB-002
Tru Sep Tris Glycine Running Buffer, 5 LiterBG-143
Tru Sep Tris Hepes Running Buffer, 5 LiterBG-163
SingleShot TGS (Tris Glycine SDS)
Running Buffer (500 ml x 20 Beutel)
DB-201
SingleShot TG (Tris Glycine)
Running / Blotting Buffer (500 ml x 20 Beutel)
DB-202
SingleShot TBS (Tris Buffered Saline)
Blottin Buffer (500 ml x 20 Beutel)
DB-203
SingleShot PBS (Phosphate Buffered Saline)
Blottin Buffer (500 ml x 20 Beutel)
DB-204
2 x Tru Sep SDS Sample Buffer (5 ml)DB-301
6 x Tru Sep SDS Sample Buffer (5 ml)DB-302
Nitrocellulose Membrane (0.45 uM, 8 x 12 CM) 25 pc/boxDB-810
Nitrocellulose Membrane (0.2 uM, 8 x 12 CM) 25 pc/boxDB-812
Nitrocellulose Membrane (0.2 uM, 7.9 x 10.5 CM) 15 pc/boxDB-813
Nitrocellulose Membrane (0.45 uM, 7.9 x 10.5 CM) 15 pc/boxDB-814
Nitrocellulose Membrane (0.45 uM, 7.9 x 10.5 CM) 5 pc/boxDB-815
Nitrocellulose Membrane (0.45 uM, 30 x 350 CM) 1 roll/boxDB-818
Nitrocellulose Membrane (0.2 uM, 8 x 8 CM) 15 pc/boxDB-824
Nitrocellulose Membrane (0.45 uM, 8 x 8 CM) 15 pc/boxDB-825

Can I use reducing agents?
NuSep gels and sample buffers do not contain reducing agents. They can be added to a sample prior to loading. Beta-mercaptoethanol and DTT are both suitable for use with our gels.

Can the gels be dried?
Yes. NuSep gels must be air-dried. Vacuum drying will cause cracking. NuSep gels can only be dried crack-free using the NuSep Gel Drying Solution. All other drying solutions will cause cracking.

Do they have a stacker gel?
All gels have a 4% stacking gel.