PCR Workstation UV-Airclean
NEW NOW AVAILABLE!
User-friendly touchscreen and energy-saving LED daylight lamp.
PCR Cabinet designed for clean operations with DNA samples.
Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.
Equiped with a flow-type bactericidal UV cleaner-recirculator AR, which provides constant decontamination inside the cabinet during operation.
This model is also available as a large version.
Request a quoteDNA-Workstation for PCR Applications
It is known that UV light causes damage to nucleic acids. Irradiation with hard UV light (254 nm) in the UV Airclean Workstation is sufficient to prevent the unwanted amplification of DNA contaminations.
UV radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.
UV cleaner-recirculator consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it sufficiently effective for DNA/RNA inactivation. The UV-recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-Airclean.
Advantages
- Ozone free high density UV decontamination
- Long living UV lamps (9,000 hours average)
- Automatic switch off of UV-lamps when the protective screen is opened
- Bactericidal flow-type recirculator providing permanent decontamination inside UV –cleaner box during operation
- Shockproof glass walls
- Low noise, low energy consumption
- Tables for installation of UV-cleaner boxes
- Patented solution: UV-Airclean with the bactericidal UV cleaner–recirculator
UPGRADE: New Specifications UV-Airclean Workstation
1. Touchscreen Interface - Faster, More Intuitive Controls
The newly introduced digital touchscreen simplifies cabinet operation by allowing users to:
Quickly set up decontamination programs.
Access all essential settings in a single menu.
Monitor UV lamp life and usage, ensuring timely replacements.
Gain easy access to the user manual and order form for consumables though QR-codes.
This update reduces setup time, enhances workflow efficiency, and minimizes operational errors.
2. Advanced UV-C Decontamination - Maximum Protection
The UV Airclean utilize powerful UV-C lamps for workspace sterilization, preventing contamination of sensitive PCR samples.
Key decontamination features include:
High-Intensity UV lamps – UV-C lamps ensure efficient sterilization of surfaces before and after use.
UV-Recirculators – Ensures continuous air purification to prevent sample cross-contamination during PCR setup.
Programmable Timer – Allows users to schedule decontamination cycles for maximum efficiency.
3. Energy Saving 8-Watt LED Daylight Lamp - Improved Illumination & Lower Energy Use
The new 8W LED daylight lamps provide bright and consistent lighting delivering approximately 1400 lux while reducing energy consumption by 50% compared to traditional lamps.
Benefits include:
Longer lifespan than standard fluorescent bulbs
Cooler operation, reducing heat buildup in the workspace
Improved energy efficiency, lowering power consumption and costs
4. UV Lamp Life Timer - Smart Preventive Maintenance
A UV lamp life tracking system, accessible via the touchscreen display, allows users to monitor lamp usage and schedule timely replacements, preventing unexpected failures and ensuring consistent and efficient sterilization performance.
5. QR-Code Access - Instant Support and Documentation
Each UV Airclean now features QR codes on the user interface, allowing instant access to:
- User manuals
- Consumable product codes
- Maintenance and troubleshooting guides
This feature simplifies maintenance and ensures that users can quickly find relevant information without searching through physical documents.
Optional Accessories
- Base frame with drawer: Order Nr. 112.0050
- Replacement tubes for UV Airclean
- UVC replacement tube - 25 Watt (Order No. 110.0420)
- White light tube - 15 Watt (Order No. 110.0429)
For our UV-Airclean customers we offer a special maintenance offer.
Order number maintenance offer: 112.0099
Order No. UV Aircelan | 112.0015 | ||
Material rear / working surface | Stainless Steel | ||
Material side panels and front | Glas (EUROGLASS, Germany) Side panels: 4 mm Upper front: 8 mm Lower front: 4 mm | ||
Dimensions exterior (W x D x H) | 700 x 580 x 555 mm | ||
Working area (W x D x H) | 645 x 490 x 420 mm | ||
Opening dimensions (fully raised protective screen) | 645 x 190 mm | ||
Weight (net / gross) | 28.8 / 39 kg | ||
Open UV lamp | 1 x 25 W built‑in bactericidal UV-C, TUV 25W 1SL/25 | ||
UV radiation level | 18 mW / cm2 / sec | ||
Radiation type | UV (λ = 253.7 nm), ozone-free | ||
Digital time setting of direct UV exposure | 1 min – 24 std / non-stop (increment 1 min) | ||
UV recirculator | 1 x 25 W (efficiency > 99% per 1 hour) | ||
Daylight lamp | 1 x 8 W LED (for working area illumination) | ||
Optical transmission | 95 % | ||
UV protection | > 96 %, UV-protection film | ||
Safety features | Automatic open UV lamp switch off when screen is open | ||
Power outlets inside the unit | Inlet for power cords and 1x built-in socket, max. 1000 W | ||
Nominal operating voltage | 100 – 240 V, 50/60 Hz | ||
Power consumption | 67 W | ||
Option | |||
Model | Table T-4 | ||
Order No. T-4 | 112.0050 | ||
![]() | |||
Description | Table with drawer and rollers Attention: The table is not delivered assembled. | ||
Dimensions (W x D x H) | 800 x 600 x 750 mm | ||
Accessories | |||
Model | Shelf F-1 For probes and reagents | Shelf P-5 For pipettes | |
![]() | ![]() | ||
Order No. | 112.0055 | 112.0056 | |
Description | Straight universal shelf for decontaminated storage of samples, reagents and small instruments above the work area. The shelves are made of transparent acrylic glass (PMMA) and ensure easy assembly and disassembly. | Holds up to 5 mechanical laboratory pipettes in vertical position above the work area. | |
Dimensions (W x D x H): | 400 x 140 x 50 mm | 230 x 140 x 50 mm |