For easy measurement of UV lamp irradiance. The most effective way to monitor the lifespan and quality control of UV light sources.

The UVX radiometer is equipped with the latest in solid state electronics. It features a rugged housing, over-ranging and a low-battery indicator.

Compact UV measuring instrument with three optional Sensors for:

  • UV 254 nm (shortwave), measurement range: 250-290 nm
  • UV 310 nm (medium wave), measurement range: 280-340 nm
  • UV 365 nm (longwave), measurement range: 335-380 nm
Request a quote

UV Measuring Instrument UVX

The digital readout is in radiometric units with a broad dynamic range from 0.1 μW/cm² to 20 mW/cm² with accuracy and precision traceable to the National Institute of Standards and Technology (NIST).

The UVX radiometer is suitable for a wide range of research and industrial applications.
Typical applications using UV light sources include genetic experiments, photochemical reactions, sterilization procedures, optical laboratory measurements, experimental biology, dermatological research, non-destructive testing, and graphics procedures.

The UVX's range switch provides selection from three intensity ranges:

  • 0 - 20 mW/cm²
  • 0 - 200 mikroW/cm²
  • 0 - 2000 mikroW/cm²

Unit includes a port for attachment of a chart recorder (user provided).

The UVX is powered by a 9-volt battery, making it completely portable. (Battery sufficient for up to 120 hours of operation)
Not included.

The UVX series sensors are designed and calibrated for measurement of radiant incidences from line type and phosphor coated mercury arc source. Depending on the measuring range, select an appropriate sensor for your radiometer.

Optional Attenuator
A 10:1 attenuator extends the reading range to up to 200 mW/cm2.
The attenuator is used to enable measurements that require high UV light intensity without overloading the detector or producing false readings.

Specifications

  • Three sensitivity ranges covering the span from 200 μW/cm 2 to 20 mW/cm 2
  • 3.5 digit liquid crystal display readout
  • Sensitivity down to 0.1 μW/cm 2
  • Outstanding ruggedness and reliability
  • Negligible sensitivity to infrared
  • Linearity of ± 1% over the total range, ± one digit
  • Readout and sensor are stored in their own storage and carrying case with room for one additional sensor
  • Light weight
  • Powered by a single 9V transistor battery
  • Long battery life (more than 120 hours of continuous operation with a single alkaline battery)
  • Automatic low voltage battery indication (”LOBAT” or “:” displayed on the LCD screen)
  • Not sensitive to capacitive or AC pick up
  • Fully interchangeable sensors for full UV band coverage
  • Automatic circuit that tests the display each time the unit is turned on
  • Read/Hold switch that allows holding any reading indefinitely
  • Automatic reverse battery connection protection circuit
  • Calibration of sensors is traceable to NIST through a standard lamp and proven laboratory techniques
  • Independent calibration of all sensors and digital Radiometers allowing complete interchangeability without reference to individual calibration factors
  • Remote sensor of small size permitting measurements to be taken in constricted areas
  • 90 cm long electrically shielded connecting cable
  • Excellent cosine response with typical curve supplied in the manual
  • A filter system which significantly reduces shortwave solarization phenomenon
  • Internal temperature correction retains the accuracy of the sensors at both high and low temperatures
  • Externally accessible zero adjust
  • Connector port for an external chart recorder (recorder not included

General Technical Data UVX Radiometer

Conversion rate2.8 readings/second
Display3.5 digital LCG
Accuracy± 2.5%
Linearity± 0.2%
Sensitivity ranges0 to 199.9 μW/cm2
0 to 1999 μW/cm2
0 to 19,99 mW/cm2
0 to 199,9 mW/cm2 (with 10:1 attenuator)
Temperature coefficient±0.025%/°C  ±1 digit, 0 to 50°C
Zero drift±0.02 uW/cm2/°C nominal 0 to 50°C
Operating temperature0 to 50°C
Humidity5% to 90%
Dimensions Radiometer (W x H x D)157 x 51 x 91 mm
Weight0.3 kg

General Technical Data UVX Sensors

Sensor accuracy± 5% (NIST standard)
Linearity± 1.0%
Temperature coefficient± 0.04%/°C nominal, 0 to 40°C
Zero drift±0.35 uW/cm2/°C nominal 0 to 50°C

Order Information

Model

Order Number

Description

UVX Radiometer110.4400 UV-Radiometer (without Sensor)
254/302/365 nm
UVX 25110.4410Sensor 254 nm
Application: 250-290 nm
UVX 31110.4411Sensor 310 nm
Application: 280-340 nm
UVX 36110.4412Sensor 365 nm
Application: 280-340 nm