EzDrop 1000C Spectrophotometer

With EzDrop spectrophotometers, measurements of sample concentrations can be made within three seconds.

The unit offers two modes for microvolume and cuvette detection, as well as an intuitive touchscreen for easy operation. These features meet a variety of nucleic acid and protein quantification needs.

EzDrop spectrophotometer can be used as a stand-alone instrument or connected to a PC for increased flexibility in converting samples to data.

EzDrop 1000C has built in 37- 45°C temperature control and stir functions to meet specific applications.

Request a quote

Spectrophotometer for Cuvette and Microvolumes

  • Independent system with clear touchpad
  • Multiple automated measurement functions allow you to quickly measure nucleic acids, proteins, cells, and other samples at the touch of a button.
  • Sophisticated design: an additional light source compensates for the lack of ambient light and minimizes errors in sample placement
    (LED Assist Light).
  • A special nano-hydrophobic layer on the sample window ensures the formation of a stable sample column.
  • The sample glass can be completely replaced, significantly reducing the possibility of residual contamination
  • CV absorbance value is <1%.
  • The special design of the detection arm reduces pressure, which in turn reduces the error rate in experiments.
  • Data exchange: USB connection

Application Areas

  • Nucleic acid and protein analysis
  • OD600 measurement
  • Analysis of microarrays and labeled proteins
  • KineticsFull spectrum scans

Cuvette Holder

Microvolume pickup with LED assist light
Sample window with nanohydrober coating ensures stable sample column.

General Technical Data EzDrop 1000C

Order No.
EzDrop 1000C
103.3910
Display7” touch screen, 1280*800 high-definition color display
ConnectivityUSB-A port x1 (Data output); USB-B port x1 (PC connection)
Footprint dimensions
(W x D x H)
206 x 333 x 166 mm
Weight3.3 kg (7.3 lbs.)
Glove suitabilitySuitable for all laboratory gloves
Internal storage32 GB flash memory
Operating voltageInput: AC 100-240 V, 50/60 Hz;
Output: DC 24 V, 2.08 A
CertificationsCE, UKCA

 

Specifications EzDrop 1000C

Microvolume Mode
Minimum sample volume1 µl
Sample number1
Pathlength0.5 mm / 0.05 mm
Light sourcePulsed xenon flash lamp
Detector type2048 element CMOS
Wavelength range190 - 1000 nm
Wavelength accuracy1.0 nm
Spectral resolution1.5 nm (FWHM bei Hg 253.7nm)
Absorbance precisionRaw: 0.0015 A (0.5 mm);
0.03 A (1 cm equivalent)
Absorbance accuracy1.5 % bei 1.0 A and 320 nm
Absorptionsbereich (entspricht 1 cm)0.04 - 400 A
Detection rangedsDNA: 2 – 20000 ng/µl
BSA: 0.06 – 600 mg/mL
Measurement time< 3 sec.
Cuvette Mode
Pathlength10, 5, 2, 1, 0.5, 0.2, 0.125, 0.1 mm
Absorbance range (1 cm equivalent)0.002 - 1.5 A
Detection rangedsDNA: 0.3 - 75 ng/µl;
BSA: 0.003 - 2.25 mg/ml
Stirring8 speeds
150 – 850 rpm
Temperature control37 - 45°C  ±0.5°C
(Quartz Cuvette)

 

Software (integrated)

Operating systemCustom Linux based OS
PC  software requirementsWindows® 7 und 10, 64 bit