Real-Time Cycler QuantGene-9600
QuantGene-9600 Real-Time cycler utilizes highly sophisticated thermoelectric cooling technology, delivering more accurate and faster quantitative fluorescence analysis that meets a broader range of user needs.
The QuantGene-9600's application spectrum includes quantitative and qualitative analyses, SNP analyses, melting curve analyses, HRM analyses, and multi-gene detection.
Classic Applications:
- Gene Expression Analysis
- Pathogen Detection
- Genetic Testing
- Environmental Monitoring
- Food Safety
QuantGene Real-Time Cycler
QuantGene-9600 meets the requirements of scientific research laboratories and is registered as a Class I (A) medical device in the EU.
The real-time cycler also meets the requirements of any diagnostic laboratory.
Specifications
- Top performance: simultaneous detection of the 96-well fluorescence signal without time difference.
- Optical fiber bundles collect fluorescence signals, reduce light transmission loss, eliminate optical path differences and edge effects, and eliminate the need for calibration.
- Highly sensitive and high-resolution CMOS detector
- Dual filter wheel is used for secondary excitation detection experiments
- Long-life semiconductor cooling guarantees 3x longer lifetime of the TE chips
- Independent 6-zone temperature control ensures more precise temperature control and more flexible gradient selection
- The 10.1-inch full-color touchscreen offers a simple user interface
Example absolute quantification with QuantGene-9600
Models and Dyes of QuantGene-9600
Model | QuantGene 4-channel | QuantGene 5-channel | QuantGene 6-channel | |||
---|---|---|---|---|---|---|
Order No. | 112.6078 | 112.6079 | 112.6080 | |||
Detection channels | F1 | F2 | F3 | F4 | F5 | F6 |
Applicable dyes | FAM, | VIC, HEX, | ROX, | Cy5 | Cy5.5 | Cy3, |
Technical Data QuantGene-9600
Sample capacity | 1 - 96 simoultaneously |
Applicable consumables | 0.2 ml 96 well PCR plates (skirted / unskirted), 0.2 ml PCR single tubes, 0.2 ml PCR 8 strip tubes |
Wavelengths | Excitation wavelength: 300 – 800 nm Emission wavelength: 500 – 800 nm |
Channels | 4 / 5 / 6 |
Dye compatibility (Depending on the model) | FAM, SYBR Green I / VIC, HEX, TET, JOE, ROX, TEXAS-RED, Cy5, Quasar-670, Cy5.5, Quasar -705, Cy3, Tamra |
Temperature setting range | 4 ~ 105°C (increment: 0.1°C) |
Heating / cooling rate | Heating rate: max 6.0 °C/s / Cooling rate: max. 5.5 °C/s |
Temperature accuracy | ≤ ±0.1°C |
Temperature uniformity | ≤ ±0.3°C |
Temperature control mode | Block / 6-zone gradient |
Fluorescence intensity test repeatability | CV ≤ 3% |
Sample volume | 5 µl - 100 μl |
Gradient temperature range | 1°C - 36°C |
Hot-lid temperature range | 30°C - 110°C (adjustable standard value: 105 °C, automatic) |
Scan mode | Full plate simultaneously |
Programs | Max. 20 segments for each program, max. 99 cycles |
Continuous operation | Yes |
Scan mode | 5.5 s |
Operating system | Windows XP/Windows Vista/Windows 7/Windows 8 |
Input power | 100 – 240 V; 50/60 Hz |
Power consumption | 1000 W |
Dimensions (W x D x H) | 490 × 290 × 391 mm |
Weight | 28 kg |
Connection | USB adapter, Bluetooth adapter |
Certification | CE, IVD |