Autoclaves

The product group "Autoclaves" contains the products Benchtop Autoclaves Series D, Media Preparators MediaPrep Series, Vertical Autoclaves Series V, ...

Benchtop Autoclaves Series D

A new dimension in technology and design!

These autoclaves don't just seem to be different; they are different. Specially developed for sterilization procedures in the laboratory, processes become easier, safer, more precise, more reproducible and validatable.

Models:

Type    Chamber dimensions
diameter x depth 
Chamber volumeDimensions*
(B x H x D)
D-65400 x 500 mm65 Liter750 x 630 x 770 mm
D-90400 x 700 mm90 Liter750 x 630 x 970 mm
D-100500 x 500 mm100 Liter850 x 730 x 810 mm
D-150500 x 750 mm150 Liter850 x 730 x 1050 mm

*All dimensions refer to housing only, they do not include the connections at the back of the housing.

All types: Heating 9kW and power supply 380 - 400 V, 50/60 Hz, 16 A

to top

Media Preparators MediaPrep Series

Prepare and sterilize microbiological media. Fast, accurate and easy to handle.

Locking of the door and loading hatch is dependent on temperature and pressure. Accidental opening is not possible! The inner vessel holder is exchangeable and easy to remove and clean. Every MediaPrep is so equipped and controlled that it can be used as a normal autoclave.

Heating and cooling systems are highly effective. 

Powerfull heating elements enable particularly rapid heating to be carried out. Rapid cooling is by water circulation and support presssure directly at the external walls of the media vessel using sterilized demineralized water. The water is brought to cooling temperature using a plate heat exchanger with a water connection. The total process time including heating, sterilizing and cooling to 50° C lasts from 60 – 120 minutes, depending on the size of the vessel, the quantity of media and the temperature of cooling water. The support pressure avoids an overboiling respectively foaming of the media. The air compressor is built-in. 

Compact Class up to 30 Liters

TypeDimensions
(B x D x H)
Chamber
Ø x height
Chamber voluminaInner vessel dimensions
Ø x height
Inner vessel voluminaWattagePower supply
MediaPrep-10550 x 655 x 530 mm296 x 250 mm17 liters270 x 222 mm12 liters3,6 kW220 - 240 V,
50/60Hz,
16 A
MediaPrep-20550 x 655 x 765 mm296 x 450 mm31 liters270 x 422 mm23 liters8,0 kW380 - 400 V,
50/60 Hz,
16 A
MediaPrep-30550 x 655 x 965 mm296 x 650 mm41 liters270 x 622 mm34 liters10,0 kW380 - 400 V,
50/60 Hz,
16 A



The Van Class up to 120 Liters

TypeDimensions
(W x D x H)
Chamber dimensions
Ø x height
Chamber voluminaInner vessel dimensions
Ø x height
Inner vessel voluminaWattagePower supply
MediaPrep-45550 x 775 x 1000 mm400 x 488 mm60 liters380 x 452 mm50 liters20 kW380 - 400 V,
50/60 Hz,
32 A
MediaPrep-65550 x 775 x 1130 mm400 x 693 mm86 liters380 x 657 mm74 liters20 kW380 - 400 V,
50/60 Hz,
32 A
MediaPrep-90650 x 895 x 1030 mm500 x 615 mm119 liters480 x 572 mm101 liters20 kW380 - 400 V,
50/60 Hz,
32 A
MediaPrep-120650 x 895 x 1160 mm500 x 795 mm156 liters480 x 752 mm133 liters20 kW380 - 400 V,
50/60 Hz,
32 A

to top

Vertical Autoclaves Series V

These autoclaves don't just seem to be different; they are different. Specially developed for sterilization procedures in the laboratory, processes become easier, safer, more precise, more reproducible and validatable.

Models:

Type    Inner vessel dimensions  
Ø  x Depth 
Inner vessel
volumina
Dimensions*
(W x H x D)
V-65400 x 500 mm65 liters550 x 960 x 780 mm
V-75400 x 600 mm75 liters550 x 960 x 780 mm
V-95400 x 750 mm95 liters550 x 1080 x 780 mm
V-100500 x 500 mm100 liters650 x 985 x 900 mm
V-120500 x 600 mm120 liters650 x 985 x 900 mm
V-150500 x 750 mm150 liters650 x 1110 x 900 mm

*All dimensions refer to housing only, they do not include the connections at the back of the housing.

All types: Heating 9kW and power supply 380 - 400 V, 50/60 Hz, 16 A

to top

Contact

You can reach LTF by phone
+49 (0) 83 82 / 98 52-0
or by e-mail to
info(at)labortechnik.com.

More Products

On our German product pages you can find more products.

Last update: 2012-04-23